The ENCLOSURE Blueprint

ENCLOSURE™ Sheathing System

ENCLOSURE™ Sheathing System comprises ENCLOSURE™ sheathing board, an adhesive ENCLOSURE™ Facade and Roofing Membrane, fixings and ENCLOSURE™ Seismic bracket. Installed behind the façade, it provides airtightness, secondary weather resistance, and structural performance while supporting the long-term durability of the building envelope.

As a critical component within The Building Agency's Integrated ENCLOSURE™ System approach, the ENCLOSURE™ Sheathing System allows performance requirements to be addressed before the façade is selected. By combining structural bracing, weather resistance, fire performance, and air-sealing functions into a single system, the ENCLOSURE™ Sheathing System helps simplify wall construction while supporting compliance with the New Zealand Building Code.

Base frame layerSheathing layerMembrane layer

Key Features

01

Rigid Air Barrier & Secondary Weather Protection

The ENCLOSURE™ Sheathing System combines the sheathing board with the ENCLOSURE™ Façade Membrane and associated flashing tapes to form a vapour-permeable air seal line within the wall assembly. Together, these components provide airtightness, secondary weather resistance, and moisture management behind the external cladding system, supporting the long-term performance of the building envelope.

02

Structural Bracing Capability

ENCLOSURE™ Sheathing System can be used as part of a wall bracing system for timber-framed buildings within the scope of NZS 3604. Wind and earthquake bracing units are achieved through the integrated performance of the ENCLOSURE™ Sheathing Board, proprietary seismic brackets, and prescribed fixing pattern, providing structural resistance as part of the complete wall assembly.

03

Supports Fire-Rated Wall Construction

ENCLOSURE™ Sheathing System can be used in both loadbearing and nonloadbearing fire rated wall construction, including fire rated systems for timber-framed buildings.

ENCLOSURE™ Sheathing System

Technical Highlights

Product type
Rigid wall sheathing system
Primary function
Airtightness and secondary weather resistance
Suitable substrates
Timber framing and light gauge steel framing
Wind zones
Up to and including Extra High (NZS 3604)
Minimum cavity requirement
18 mm drained cavity
Bracing capability
Can be used as a wall bracing system for timber-framed buildings within the scope of NZS 3604
Fire-rated construction
Suitable for tested fire-rated wall assemblies (AS 1530.4:2014)

Application

Scope of Use

ENCLOSURE™ Sheathing System is suitable for external wall pre-cladding applications where:

  • Timber framing is designed within the scope of NZBC E2/AS1
  • Light gauge steel framing complies with NASH Standards
  • Buildings are located in wind zones up to and including Extra High
  • Cladding systems are installed over a minimum 18 mm drained cavity
  • Walls are located at least 1 metre from the relevant boundary

The system may also be used as part of fire-rated wall construction and timber-framed bracing systems within the scope of its testing and supporting documentation.

Compliance

Compliance with the New Zealand Building Code

ENCLOSURE™ contributes to compliance with the following NZBC clauses when used as part of a compliant wall assembly:

Structure – B1

Contributes to compliance with B1.3.1, B1.3.2, B1.3.3 and B1.3.4 requirements for structural performance.

Durability – B2

Currently undergoing testing to demonstrate compliance with B2 durability requirements B2.3.1 (a) & B2.3.1 (b).

Protection from Fire – C3

Contributes to compliance when incorporated into tested fire-rated wall assemblies C3.6 & C3.7.

External Moisture – E2

Contributes to compliance E2.3.2 when used within drained and ventilated cavity wall systems.

Hazardous Building Materials – F2

Complies with the requirements of NZBC Clause F2.3.1.

Why specify

Why Architects Specify ENCLOSURE™ Sheathing System

Architects specify the ENCLOSURE™ Sheathing System because it shifts building envelope design from a façade-first approach to a performance-first methodology.

  • Provides airtightness and secondary weather resistance
  • Contributes to structural bracing performance
  • Compatible with fire-rated wall construction
  • Supports timber and steel-framed building systems
  • Compatible with a wide range of cladding materials
  • Forms a key component within an integrated enclosure strategy

ENCLOSURE™ Sheathing System helps create high-performance wall assemblies where structure, weather resistance, fire performance, and façade systems work together as a coordinated whole.

Assurance

Warranty & Maintenance

Sheathing Board, the manufacturer provides a limited warranty covering manufacturing defects for a duration of 5 years from date of purchase. Adhesive Membrane, the manufacturer provides a warranty covering deviations from product specification under normal use conditions for a duration of 10 years from the date of purchase.

Installation guide, BPIRs, EPD, and brochures

Document library

Access the full ENCLOSURE™ Sheathing System technical library including installation guide, BPIR certifications, Engineers Judgement Report, EPD, and Brochures

Resources

Document library

Open in new tab

BPIR

TBA ENC BPIR Sheathing MAY26

Download PDF

Building product information requirements document for ENCLOSURE Sheathing System

If your browser blocks the embedded preview, use the open or download link above.

Explore the ENCLOSURE Systems

  • Sheathing SystemSheathing System
  • A&B SystemA&B System
  • Hook & Pin SystemHook & Pin System
  • T50 SystemT50 System
  • Top Hat SystemTop Hat System
  • Alpharail SystemAlpharail System
  • Barracuda Brick SlipBarracuda Brick Slip
  • Isotherm SystemIsotherm System

Need Help Specifying?

Our technical team can assist with product selection, CAD details, and sample requests for your next project.

View All Systems

Get in Touch

Tell us about your project and we'll help with specification.

Enquire About This System

ENCLOSURE™ Sheathing System | The Building Agency | The Building Agency